Line 
1; BCRA Grade 3 specification file
2
3; tape error
4; 95% of readings are within 0.5m (3 S.D.)
5*sd length   0.15 metres
6
7; compass error
8; 95% of readings are within 10 degrees (3 S.D.)
9*sd bearing backbearing   3.33 degrees
10
11; clino error
12; 95% of readings are within 10 degrees (3 S.D.)
13*sd gradient backgradient 3.33 degrees
14
15; station position error
16; 95% of positions are within 0.1m (3 S.D.)
17*sd position 0.15 metres