1;BCRA Grade 3 specification file
2
3;tape error
4*SD tape     0.15 metres   ;95% of readings are within 0.5m (3 S.D.)
5
6;compass error
7*SD compass  3.33 degrees  ;95% of readings are within 10 degrees (3 S.D.)
8
9;clino error
10*SD clino    3.33 degrees  ;95% of readings are within 10 degrees (3 S.D.)
11
12;station position error
13*SD position 0.15 metres   ;95% of positions are within 0.1m (3 S.D.)