RELEASE/1.2debug-cidebug-ci-sanitisersfaster-cavernloglog-selectstereostereo-2025walls-datawalls-data-hanging-as-warningwarn-only-for-hanging-survey
        
      
      
        
  | Line |   | 
|---|
| 1 | ; BCRA Grade 5 specification file | 
|---|
| 2 |  | 
|---|
| 3 | ; tape error | 
|---|
| 4 | ; 95.44% of readings are within 0.1m (2 S.D.) | 
|---|
| 5 | *sd length    0.05 metres | 
|---|
| 6 |  | 
|---|
| 7 | ; compass error | 
|---|
| 8 | ; 95.44% of readings are within 1 degree (2 S.D.) | 
|---|
| 9 | *sd bearing backbearing   0.5 degrees | 
|---|
| 10 |  | 
|---|
| 11 | ; clino error | 
|---|
| 12 | ; 95.44% of readings are within 1 degree (2 S.D.) | 
|---|
| 13 | *sd gradient backgradient 0.5 degrees | 
|---|
| 14 |  | 
|---|
| 15 | ; station position error | 
|---|
| 16 | ; 95.44% of positions are within 0.1m (2 S.D.) | 
|---|
| 17 | *sd position  0.05 metres | 
|---|
       
      