1; BCRA Grade 5 specification file
2
3; tape error
4; 95.44% of readings are within 0.1m (2 S.D.)
5*sd length    0.05 metres
6
7; compass error
8; 95.44% of readings are within 1 degree (2 S.D.)
9*sd bearing backbearing   0.5 degrees
10
11; clino error
12; 95.44% of readings are within 1 degree (2 S.D.)
13*sd gradient backgradient 0.5 degrees
14
15; station position error
16; 95.44% of positions are within 0.1m (2 S.D.)
17*sd position  0.05 metres
Note: See TracBrowser for help on using the repository browser.