source: git/lib/bcra5.svx @ 1b69705

RELEASE/1.2debug-cidebug-ci-sanitiserswalls-data
Last change on this file since 1b69705 was 4f38f94, checked in by Olly Betts <olly@…>, 8 years ago

Implement support for tape on backsights

If you're using something like a disto-x, you'll get a distance reading for the
backsight too.

Fixes #71, reported by Erin Lynch.

  • Property mode set to 100644
File size: 439 bytes
Line 
1; BCRA Grade 5 specification file
2
3; tape error
4; 95.44% of readings are within 0.1m (2 S.D.)
5*sd length backlength     0.05 metres
6
7; compass error
8; 95.44% of readings are within 1 degree (2 S.D.)
9*sd bearing backbearing   0.5 degrees
10
11; clino error
12; 95.44% of readings are within 1 degree (2 S.D.)
13*sd gradient backgradient 0.5 degrees
14
15; station position error
16; 95.44% of positions are within 0.1m (2 S.D.)
17*sd position  0.05 metres
Note: See TracBrowser for help on using the repository browser.