source: git/lib/bcra5.svx @ d4d6909

RELEASE/1.2debug-cidebug-ci-sanitisersstereowalls-data
Last change on this file since d4d6909 was 770157e, checked in by Olly Betts <olly@…>, 22 years ago

Resolved mismatch between bcra3.svx, bcra5.svx, and defaults in commands.c.

git-svn-id: file:///home/survex-svn/survex/trunk@1931 4b37db11-9a0c-4f06-9ece-9ab7cdaee568

  • Property mode set to 100644
File size: 427 bytes
RevLine 
[b14f44f]1; BCRA Grade 5 specification file
[adaa778]2
[b14f44f]3; tape error
[770157e]4; 95.44% of readings are within 0.1m (2 S.D.)
5*sd length    0.05 metres
[adaa778]6
[b14f44f]7; compass error
[770157e]8; 95.44% of readings are within 1 degree (2 S.D.)
9*sd bearing backbearing   0.5 degrees
[adaa778]10
[b14f44f]11; clino error
[770157e]12; 95.44% of readings are within 1 degree (2 S.D.)
13*sd gradient backgradient 0.5 degrees
[adaa778]14
[b14f44f]15; station position error
[770157e]16; 95.44% of positions are within 0.1m (2 S.D.)
17*sd position  0.05 metres
Note: See TracBrowser for help on using the repository browser.