source: git/lib/bcra3.svx @ 9e8ff8e

RELEASE/1.2debug-cidebug-ci-sanitisersstereowalls-data
Last change on this file since 9e8ff8e was 4f38f94, checked in by Olly Betts <olly@…>, 8 years ago

Implement support for tape on backsights

If you're using something like a disto-x, you'll get a distance reading for the
backsight too.

Fixes #71, reported by Erin Lynch.

  • Property mode set to 100644
File size: 446 bytes
Line 
1; BCRA Grade 3 specification file
2
3; tape error
4; 95.44% of readings are within 0.5m (2 S.D.)
5*sd length backlength     0.25 metres
6
7; compass error
8; 95.44% of readings are within 2.5 degrees (2 S.D.)
9*sd bearing backbearing   1.25 degrees
10
11; clino error
12; 95.44% of readings are within 2.5 degrees (2 S.D.)
13*sd gradient backgradient 1.25 degrees
14
15; station position error
16; 95.44% of positions are within 0.5m (2 S.D.)
17*sd position 0.25 metres
Note: See TracBrowser for help on using the repository browser.