[b14f44f]1; BCRA Grade 3 specification file
[adaa778]2
[b14f44f]3; tape error
[770157e]4; 95.44% of readings are within 0.5m (2 S.D.)
5*sd length 0.25 metres
[adaa778]6
[b14f44f]7; compass error
[770157e]8; 95.44% of readings are within 2.5 degrees (2 S.D.)
9*sd bearing backbearing   1.25 degrees
[adaa778]10
[b14f44f]11; clino error
[770157e]12; 95.44% of readings are within 2.5 degrees (2 S.D.)
13*sd gradient backgradient 1.25 degrees
[adaa778]14
[b14f44f]15; station position error
[770157e]16; 95.44% of positions are within 0.5m (2 S.D.)
17*sd position 0.25 metres